Microsonic LCA-2 Manual do Utilizador Página 20

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 51
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 19
Page 20 of 51 Changing parameters on distance measuring sensors
mm: the measured distance value is indicated in mm and/or cm
0...100%: the measured distance value is indicated as percentage value of the analogous
characteristic, be-gun from the sensor-near vertex up to the sensor-far vertex
100...0%: the measured distance value is indicated as percentage value of the analogous
characteristic, be-gun from the sensor-far vertex up to the sensor-near vertex
NOISE INTERFERENCE FILTER
Only for pico+ or lcs+ sensors
Interfering ultrasonic signals, which are not produced by the sensor itself can be suppressed by the
activation of the noise interference filter.
Vista de página 19
1 2 ... 15 16 17 18 19 20 21 22 23 24 25 ... 50 51

Comentários a estes Manuais

Sem comentários