Microsonic LCA-2 Manual do Utilizador Página 40

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 51
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 39
Page 40 of 51 Parameter change in the web edge sensor bks+
TEACH-IN-METHODEN
To adjust the zero position of the edge to be controlled, the sensor can be calibrated with two options.
Completely freeing the fork from the web material
push , then completely fill sensor fork and
push .
Or align the web edge inside the fork with the two marks to ensure a 50 % coverage of the sound path,
then push .
Ready.
ANALOG OUTPUT SETTING
The analog output can be adjusted so that it supplies current or voltage. The characteristic can be
selected as rising or falling.
Voltage / Current Increasing: voltage / current increases with higher coverage
Voltage / Current falling: voltage / current drops with higher coverage
SWITCH OUTPUT SETTING
The switched output of the bks+../FIU or bks+../F can be used e.g. for monitoring purposes. He switches
around the (adjustable) center in a (adjustable) window.
Vista de página 39
1 2 ... 35 36 37 38 39 40 41 42 43 44 45 ... 50 51

Comentários a estes Manuais

Sem comentários