Microsonic LCA-2 Manual do Utilizador Página 33

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 51
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 32
Parameter change in the double sheet control Page 33 of 51
OPERATING MODES
You can select from the following operating modes:
Free-Run-Mode with 3 predifined sensitivity classes and additional teach-in mode, e.g. for
scanning wafers glued with a water film.
Free-Run-Mode with 4 independent teach-in classes.
Trigger-Mode with 2 predefined sensitivity classes and additional teach-in mode
Level or edge triggered mode, e.g. for applications in the imbricated stream.
FREE RUN 3 PREDIFINED SENSITIVITY CLASSES + 1 TEACH-IN
The dbk+4 operates in the free-run mode ex-works. In the free-run mode, the dbk+4 performs
measurements cyclically.
Should measurements be taken in the imbricated stream, then an external trigger signal can
individually trigger each measurement. To this end, the trigger mode can be parameterized with the aid of
the LCA-2 LinkControl adapter available as an accessory and the LinkControl software.
FREE RUN 4 TEACH-IN
If the dbk+4 is parameterized in Free-Run mode, you can teach up to 4 different materials.
The sensitivity classes "Standard", "Thick", "Thin" und "Teach-in" can be customized..
With the appropriate buttons the teached classes of materials can be brought back to the default.
Vista de página 32
1 2 ... 28 29 30 31 32 33 34 35 36 37 38 ... 50 51

Comentários a estes Manuais

Sem comentários